SBC ADV PLUS - Low Power Series
Ellcee Nautical Supplies Co.Ltd.
Camilleri Marine
162A Ta'Xbiex Seafront
Gzira - Malta.
Website:www.ellcee.com
Tel: (+356) 21 346 320
Fax: (+356) 21 345 414
Mob: (+356) 9943 9954
E-mail:camarine@ellcee.com
Contact: Lawrence Camilleri
(Managing Director )
250/DR - 285/DR
Important advantages:
•
Multiple outputs in order to charge more groups of batteries (internal battery isolator diodes).
•
Charge selector for liquid/gel electrolyte batteries.
•
Low residual fluctuation on output (ripple lower than 30 mV RMS).
•
Compatible with every kind of generator.
•
Can work in a wide range of ambient temperatures.
3 Step automatic charge
BULK phase (constant current)
ABSORPTION phase (constant voltage)
FLOAT phase (maintenance)
Universal AC Network: models DR
Protections:
• Reverse polarity (with internal fuse)
• Overload
• Output short circuit
• Overheating
Model
SBC ADV PLUS 250/250 DR
SBC ADV PLUS 285/285 DR
Max output current (1)
25 A
12 A
Charge absorption voltage
14,1 Vdc (14,4 Vdc gel)
28,2 Vdc (28,8 Vdc gel)
Charge float voltage
13,5 Vdc (13,8 Vdc gel)
27 Vdc (27,6 Vdc gel)
Residual ripple (2)
30mV RMS max
Charging characteristics
Automatic in three stages IUoU
Number of output (3)
3
2
Supply voltage (4)
260 ÷ 207 Vac (260 ÷ 207 Vac or 130 ÷ 103 Vac (5) - (*) )
Frequency
45 ÷ 66 Hz
Max absorption (230 Vac) (6)
3,2 A
3,0 A
Max absorption (115 Vac) (6) - (*)
6,4 A
6,0 A
Operating temperature
-20 ÷ +70 Cº, with power reduction over i +50 Cº
Cooling
Forced, with controlled fan
Case material
Alluminium Cycoloy®
Dimensions (W x H x D)
155 x 268 x 75 mm
Weight
2,3 Kg
Safety classification
EN 60335-2-29
EMC Class
EN 55022/B
(*) Only DR models
Maximum value at normal use or in short circuit.
At maximum output current on resistive load.
Each output can supply the maximum value of nominal current. The sum of the currents supplied from each output can not exceed the maximum nominal value of the equipment.
Without power derating.
The battery charger measure the input AC voltage and choose the correct working input range.
With supply voltage specified as and output current equal to the maximum nominal value.